Type mc cable with a nonmetallic jacket can also be used in a wet location.
Pvc coated mc cable uses permitted.
Jacketed metal clad cable and teck cable metal clad cable type mc ref.
If installed in a wet location the metallic cover must be impervious to moisture or the insulated conductors must be listed for use in a wet location.
1 2 nec articles 501 502 503 530 galvanized steel armor with pvc jacket.
330 12 1 subject to physical damage.
Sustainability careers contact us legal disclaimer.
Please enter a valid email address.
Nec article 334 metal clad cable type mc is a factory assembly of one or more conductors each individually insulated and enclosed in a metallic sheath of interlocking tape or a smooth or corrugated tube metal clad cable type mc is rated for use up to 5 000 volts.
Please refer to nec article 330 and your local authority having jurisdiction for additional information.
Southwire patents southwire canada california supply chain act recalls.
The most common is the pvc coated sunlight resistant direct burial listed mc cable in the image.
Products ordering resources about us.
Previous wording did not require the corrosion resistant jacket as a prerequisite to use the 3 conditions.
The afc cable systems 250 ft.
This cable is great for signal circuits in wet dirty or oily locations can be buried directly in earth or concrete surface mounted or trenched for use in parking deck or parking lot applications golf courses docks.
The revised 2014 code language makes it clear that a corrosion resistant jacket must be present over the cable and then the 3 conditions apply.
Also used in continuous runs to outdoor or underground swimming pool motors pumps and related equipment per nec 680 fished exposed or concealed cable trays direct sunlight and hazardous locations up to class i ii div.
The uses permitted for mc cable are governed by nec article 330 and any applicable local codes.
Section 330 10 a 13 covering the permitted uses of type mc cable contains a major change for the 2002 nec.
Afc also offers parking deck lot cable pvc jacketed mc cable which is mc cable with galvanized steel armor with a pvc jacket.
Type mc cable isn t permitted to be used where.
Armorlite type mc pvc jacketed neutral per phase cable view pdf.
Direct burial in the earth or embedded in concrete.
Email has been submitted successfully.
2 exposed to the destructive corrosive conditions in a or b below unless the metallic sheath or armor is resistant to the conditions or protected by material resistant to the conditions.